NONFIR

Industrial

Fixed Manual Fire Monitor

Tiller and gear-controlled fire monitors for permanent and semi-permanent fire protection installations. SS 304/316 construction, water and foam capability, covering flows from 1200 to 4800 LPM across 12+ model variants.
Specification Details
Monitor Body SS 304 / 316
Nozzle Options SS+Brass / Aluminum / SS+Al
Control Type Tiller / Gear (Handwheel)
Jetting Pattern Stream / Fog / Stacked Tips
Flange Standard BS4504 · ANSI 150 · GB
Inlet Size 2.5 / 3 / 4 inch
Agent Water · Water + Foam
Working Pressure 8 bar continuous
Body Standard Stainless steel across TFS and WFS series
1

Product Series

 

The TFS (Tiller Control) and WFS (Gear Control) series cover the full range of manual fire monitor requirements - from compact single-outlet installations to large-scale terminal protection. Choose by control type, nozzle configuration, and required flow capacity.

SS Nozzle Tiller Control

TFS1 · Tiller · Stream/Fog

NONFIR Industrial  Fixed Manual Fire Monitor

Full stainless steel construction including SS 304/316 nozzle with brass trim. Dual-mode jetting for both straight stream firefighting and 120° fog coverage.

 

Flow Range 1200 – 2400 LPM
Max Reach 65 m
Inlet 2.5 / 3 / 4″

Aluminum Nozzle Tiller Control

TFS1 / TFS2 · Tiller · Stream/Fog

NONFIR Industrial  Fixed Manual Fire Monitor

Extended range series with aluminum alloy nozzle. TFS2 models scale up to 4800 LPM for refinery and tank farm perimeter protection requiring long throw distances.

 

Flow Range
1200 – 4800 LPM
Max Reach
85 m
Inlet
2.5 / 3 / 4″

Stacked Tips Tiller Control

TFS1 / TFS2 · Tiller · Stacked Tips

NONFIR Industrial  Fixed Manual Fire Monitor

Selectable multi-flow nozzle system on a single unit. Adjustable output without tool changes, ideal for scenarios where required flow rate may vary across incidents.

 

Flow Range
1200 – 4800 LPM
Max Reach
85 m
Inlet
2.5 / 3 / 4″

Gear Control Stream / Fog

WFS1 / WFS2 · Gear · Stream/Fog

NONFIR Industrial  Fixed Manual Fire Monitor

Precision handwheel gear control for fixed installations where repeatable, fine directional adjustment is required. Available with SS+Brass or aluminum alloy nozzle.

 

Flow Range
1200 – 4800 LPM
Max Reach
85 m
Inlet
2.5 / 3 / 4″

Water Foam Monitor SP Nozzle

TFS / WFS · Tiller & Gear · SP NozzleNONFIR Industrial  Fixed Manual Fire Monitor Dual-agent capability in a single monitor. The SP nozzle delivers both water straight stream and AFFF foam, with foam throw reaching 70 m for flammable liquid fire suppression.

 

Flow Range
1440 – 3840 LPM
Water Reach
50 – 75 m
Foam Reach
42 – 70 m

Water Foam Monitor SQ Nozzle

TFS / WFS · Tiller & Gear · SQ NozzleNONFIR Industrial  Fixed Manual Fire Monitor SQ nozzle variant matching the performance envelope of the SP series. Offers an alternative nozzle geometry for specific foam concentrate compatibility or system integration requirements.

 

Flow Range
1440 – 3840 LPM
Water Reach
50 – 75 m
Foam Reach
42 – 70 m
2

Typical Applications

 
Oil Refinery Plant in Fire

Petrochemical & Refinery Plants

High-capacity TFS2 and WFS2 monitors protect process units, pipe racks, and storage areas in oil refineries and petrochemical complexes. The 4800 LPM maximum flow and 85 m reach meet the protection distances mandated by NFPA 15 for large industrial installations.
productcate-768-512

Marine & Offshore Facilities

The SS 316 body option provides superior resistance to seawater chloride corrosion, making TFS and WFS monitors suitable for jetty heads, offshore platforms, LNG terminals, and ship-loading facilities where marine-grade materials are specified.
Fire water monitor in power plant

Power Generation & Utilities

Coal yards, transformer bays, turbine halls, and cooling tower areas benefit from tiller-control monitors for rapid manual response. The stacked tips series allows operators to select the appropriate flow rate for the hazard without equipment changeover.
Foam Report for Simple and Precise Documentation - Rosenbauer

Airport & Aviation Infrastructure

Fuel hydrant systems, aircraft maintenance hangars, and apron areas require both water and foam suppression capability. The TFS and WFS foam monitor series provides the dual-agent flexibility required by ICAO and CAA fire protection standards for aviation facilities.
3

Technical Specifications

Series Control Nozzle Material Spray Pattern Flow Range (LPM) Max Reach Inlet Size Agent
TFS1.SF / SS Tiller SS 304/316 + Brass Stream + 120° Fog 1200–2400 65 m 2.5" / 3" / 4" Water
TFS1–2.AF / AS Tiller Aluminum Alloy Stream + 120° Fog 1200–4800 85 m 2.5" / 3" / 4" Water
TFS1–2.AZ-4 Tiller Aluminum Alloy Stacked Tips 1200–4800 85 m 2.5" / 3" / 4" Water
TFS1–2.AZ-1 Tiller Aluminum Alloy Straight Stream 1200–4800 85 m 2.5" / 3" / 4" Water
WFS1.SF / SS Gear (Handwheel) SS 304/316 + Brass Stream + 120° Fog 1200–2400 65 m 2.5" / 3" / 4" Water
WFS1–2.AF / AS Gear (Handwheel) Aluminum Alloy Stream + 120° Fog 1200–4800 85 m 2.5" / 3" / 4" Water
WFS1–2.AZ-4 Gear (Handwheel) Aluminum Alloy Stacked Tips 1200–4800 85 m 2.5" / 3" / 4" Water
WFS1–2.AZ-1 Gear (Handwheel) Aluminum Alloy Straight Stream 1200–4800 85 m 2.5" / 3" / 4" Water
TFS1–2.SP / SQ Tiller SS + Aluminum Straight Stream 1440–3840 Water: 75 mFoam: 70 m 2.5" / 3" / 4" Water + Foam
WFS1–2.SP / SQ Gear (Handwheel) SS + Aluminum Straight Stream 1440–3840 Water: 75 mFoam: 70 m 2.5" / 3" / 4" Water + Foam

All specifications at 8 bar. Contact us for full model-by-model data sheet.

 

Why NONFIR

Premium Material Construction

All NONFIR fire monitors are manufactured using SS304 or SS316 stainless steel, providing excellent corrosion resistance and long-term durability in industrial, marine, and offshore environments. Material specifications are clearly stated in every quotation and supporting documentation is available upon request.

Tested Performance

Flow rates, throw distances, and spray patterns are based on actual performance testing under rated operating conditions. Detailed technical datasheets are available for each monitor model to support engineering design, project approvals, and specification reviews.

Reliable Delivery

Standard monitor models are maintained with stable production schedules to support project requirements. Delivery times are confirmed during the quotation stage, allowing contractors and distributors to plan procurement with confidence.

Technical Application Support

Our engineering team assists with monitor selection, nozzle matching, and application recommendations. Whether for water monitors, foam monitors, tank farms, petrochemical facilities, or industrial fire protection systems, we help customers select the most suitable solution.

International Project Compatibility

NONFIR monitors are available with multiple flange standards, including ANSI, BS, and GB configurations. This flexibility simplifies installation across different markets and project specifications without requiring additional modifications.

Complete Monitor Range

From manual water monitors to gear-operated foam monitors and high-flow industrial units, NONFIR offers a comprehensive range of fire monitor solutions. Customers benefit from sourcing multiple monitor types from a single manufacturer with consistent quality and technical support.

As one of the leading fixed manual fire monitor manufacturers and suppliers in China, we offer a wide range of products with superior quality. Please feel free to buy customized fixed manual fire monitor made in China here from our factory. For price consultation, contact us.

Send Inquiry
Certified Sprinklers for Your Safety
FM Approved Fire Sprinkler Systems Designed for Your Facility
contact us